Condenser
 

Glass-lined Disk-type Condenser

[Main technical conditions]

Application Temperature:-20-200℃

Application Pressure:Inside Machine≤0.085MPa;Inside stuff≤0.4MPa

heat transmission coefficient:485Kcal/hm2C

Porcelain layer withstanding voltage:20KV

Porcelain layer thickness:0.8-1.8mm

Flange flatness:≤0.3% DN

Flange circular degree :≤0.4% DN

The Enamel physical and chemical properties and the porcelain facing appearance come up to HG2432-93 and Q/320281 ADA02--1996 specifications.

[Appearance Dimensions]

W-0.5
heat inter-changing area m2 middle-level number of panels / piece overall height H(mm) external diameter φ(mm) Weight kg
1.5 2 670 700 230
2 3 760 700 270
2.5 4 850 700 320
3 5 950 700 360
3.5 6 1040 700 410
4 7 1130 700 450
4.5 8 1220 700 500
5 9 1320 700 550
6 11 1500 700 650
6.5 12 1600 700 700
7 13 1680 700 750

W-1
heat inter-changing area m2 middle-level number of panels / piece overall heightH (mm) external diameter φ(mm) Weight kg
5 4 1000 960 580
6 5 1100 960 660
7 6 1200 960 740
8 7 1290 960 820
9 8 1380 960 900
10 9 1470 960 980
11 10 1560 960 1060
12 11 1650 960 1140
13 12 1740 960 1220
14 13 1830 960 1300
15 14 1920 960 1380

Picture Marks W-0.5 W-1
φ 450mm 660mm
R 220mm 220mm
D φ20mm φ22mm
A medium entrance DN80 medium entrance DN100
B water pipes are connected by “DI”tube.

[Properties]

The product consists of W-2 model and W-0.5 model. The condensation area of W-0.5 model is cupped plate, each 0.5m2. And the equipment's external diameter is φ700mm. The W-1 model cupped plate is 1m2 each and the equipment external diameter is φ960mm. The detail specifications of 1.5-15m2 series are optional according to the condensation number.

The product is small cubage and light with a compact structure.

The condensation of the thermal current can be achieved by the antiphase flowing heat exchange of thermal current and cooling water.

This product's condensation efficiency can be improved by 1-2 times, compared with the glass lining telescopefeed condensator in same acreage and the carbon heat exchanger.

When the components damage appears, can partially renovate or reduce the monolithic.

Glass-lined Disk-type Condenser

Nominal heat exchange area (m2)
D1
D2
D3
D4
D5
D6
D7
H0
H
H1
H2
H3
Nominal diameter of tube
a
b,c
d,f
e
2
300
400
500
600
716
200
200
977
800
400
380
158
80
20
20
65
2.5
300
400
500
600
716
200
200
1277
1100
500
380
158
80
40
25
65
3
400
500
600
700
816
250
235
1191
1000
560
385
165
100
40
40
65
4
400
500
600
700
816
250
235
1441
1250
700
385
165
100
40
40
65
6
500
600
700
800
928
300
250
1793
1600
800
460
180
100
40
40
80
8
600
700
800
900
1042
350
250
2085
1800
900
490
200
125
40
40
80
10
700
800
900
1000
1164
400
250
2206
2010
1100
490
200
125
40
40
80
 
 
 
 
Copyright(C)2005,Jiangyin Chemical Equipment Plant All Rights Reserved.
Supported by ChemNet ChinaChemNet Toocle